Showing results: 841 - 855 of 2470 items found.
-
42460 -
Pulse Instruments
Two channels of 32 MHz clock drivers with up to 20 volt amplitude. The output voltage range is ±20 V, with independent high and low voltage settings. The inputs to the Card can be optically isolated. The card also contains voltage and current sense capability, which allows muxing of the current or voltage output measurements from all the Driver Channels in the system to a single DVM. The card allows independent programming of the rise and fall time of each channel one nanosecond increments.
-
40461 -
Pulse Instruments
Two channels of 8 to 10 MHz drivers (25 V amplitude). The output voltage range is ±25V, with independent high and low voltage settings. The inputs to the Card are optically isolated. The card also contains voltage and current sense capability, which allows muxing of the current or voltage output measurements from all the Driver Channels in the system to a single DVM. The card allows independent programming of the rise and fall time of each channel as low as one nanosecond increments.
-
"V45A" -
Anfatec Instruments AG
This low-noise 3-channel high voltage amplifier V45A wasdesigned for the control of tube scanners in scanning probemicroscopes. Three inputs with 10 V are amplified into twoasymmetric output voltages (Xout = 45 V and - Xout= - 45V) in the channels X and Y, while the Z-channel is 90 V relativelyto ground.
-
Tabor Electronics Ltd.
Low power supply rails, a main part of the PXI, cPCI and PCI equipment, are a common cause for an inability to produce high voltage output. Tabor Electronics’ new amplifiers convert the supply rails to higher voltage suitable for signals up to 40Vp-p, thus solving thit problem.
-
PD-28 -
Standard Electric Works Co., Ltd
● Measures both AC and DC voltages with digital multitester.● Are typically used to measure high voltages in TV sets, power supplies and instruments in laboratories.● Lightweight and rugged.● 2 available contact tips: round needle tip for normal use and a special flat spring-type for CRT anode.
-
PD-40AM -
Standard Electric Works Co., Ltd
● Measures positive polarity DC voltages up to 40kV.● Lightweight and rugged.● 2 available contact tips: round needle tip for normal use and a special flat spring-type for CRT anode.● Are typically used to measure high voltages in TV sets, power supplies and instruments in laboratories.
-
PD-20 -
Standard Electric Works Co., Ltd
● Measures both AC and DC voltages with digital multitester.● Are typically used to measure high voltages in TV sets, power supplies and instruments in laboratories.● Lightweight and rugged.● 2 available contact tips: round needle tip for normal use and a special flat spring-type for CRT anode.
-
LS9923 -
Lisun Electronics Inc.
LS9923 programmable withstanding voltage & insulation test system is high-performance testing device special for AC&DC Withstanding Voltage and Insulation Resistance Test, It allows setting the output voltage. The warning value,testing time and some other parameters can be set in the screen.It with a variety of automatic test functions. The testing is quick and high accuracy which is not only applied in the production line but also in the develop research.
-
PeakTech Prüf- und Messtechnik GmbH
Due to the high safety requirements in service workshops, schools and industry, an isolating transformer is an absolute prerequisite for carrying out professional repair work. Galvanic isolation between primary and secondary voltage during measurements and repairs on open devices guarantees a high safety standard for the user. Of course, galvanic isolation from the mains voltage also offers other advantages in electronics development, audio technology and many other areas.
-
PeakTech Prüf- und Messtechnik GmbH
Due to the high safety requirements in service workshops, schools and industry, an isolating transformer is an absolute prerequisite for carrying out professional repair work. Galvanic isolation between primary and secondary voltage during measurements and repairs on open devices guarantees a high safety standard for the user. Of course, galvanic isolation from the mains voltage also offers other advantages in electronics development, audio technology and many other areas.
-
B-1002 -
Ruetz Technologies GmbH
Ross High Current Switches are available up to 36,000 amps continuous and over 1,700,000 amps 20µsec RC pulse, with voltage ratings of 6 volts to 400kV peak test. Standard Ross high current switches are built with 80 to 120psi air cylinder actuators. Air cylinder or motor operated for high contact force. Arcing contacts optional for closing current. G-10 epoxy glass laminate is standard insulation on most models. G-7 silicone glass is used on models available for RF applications above 100kHz. Most Ross high current switches are available with additional lengths of insulation, where the high voltage contacts need to be spaced at a greater distance from the actuator and control circuit. Voltage withstand value is at least doubled and the interrupt capability is much greater when high current switches are immersed in insulating oil, fluid or SF6 gas. For gas atmosphere, no modifications are necessary; however, oil or fluid immersion requires modification at a slight extra cost.
-
B-1002 -
ROSS ENGINEERING CORPORATION
Ross High Current Switches are available up to 36,000 amps continuous and over 1,700,000 amps 20µsec RC pulse, with voltage ratings of 6 volts to 400kV peak test. Standard Ross high current switches are built with 80 to 120psi air cylinder actuators. Air cylinder or motor operated for high contact force. Arcing contacts optional for closing current. G-10 epoxy glass laminate is standard insulation on most models. G-7 silicone glass is used on models available for RF applications above 100kHz. Most Ross high current switches are available with additional lengths of insulation, where the high voltage contacts need to be spaced at a greater distance from the actuator and control circuit. Voltage withstand value is at least doubled and the interrupt capability is much greater when high current switches are immersed in insulating oil, fluid or SF6 gas. For gas atmosphere, no modifications are necessary; however, oil or fluid immersion requires modification at a slight extra cost.
-
40-619-302 -
Pickering Interfaces Ltd.
The 40-619-302 is a high density PXI 2 A multiplexer module in dual 64-channel configuration using high quality electro-mechanical signal relays allowing each channel to switch current up to 2 A and voltage up to 250 VAC/DC - Single
-
F-712.PM1 -
Physik Instrumente GmbH & Co. KG
This photometer can convert an optical signal into a voltage signal in high resolution and with an extremely high bandwidth. The design of the optical input enables measuring of the optical signal independent of the position of the optical fiber in the connector. Wavelength range: 400 to 1550 (1) nm
-
DP-30K -
PINTEK Electronics
*30KVp-p, High Voltage Model .*Input Impedance 81.6MΩ//1PF *x200, x2000 Attenuator, Easy to Convert.*Separating Design(Standard No.114205)*Convenient & Durable.